HGF Series Service Procedure
28
Figure 74
Figure 73
Figure 72
Figure 71
22. Grasp the drive link (16) and rotate
the metering package by hand to
make sure the parts do not bind.
The rotor (24) should orbit inside
the stator (25). If they bind,
disassemble the metering
package, correct the cause, and
repeat the assembly and
concentricity procedures. See
FIGURE 71.
Check rotor movement
23. Apply clean grease to the metering
ring seal ring (3). Position the seal
ring in the metering ring seal
groove opposite to the end with
the alignment pin holes. Stack the
metering ring (17) into place, over
the four bolts (40), with the seal
ring towards the upper cover plate
(32), and an alignment pin hole on
the metering ring in line with and
on the same side as the alignment
groove on the side of the upper
cover plate. See FIGURE 72.
This is required so that the other
components can be aligned
correctly.
Install metering ring
CAUTION: Be sure the seal ring (3)
does not slip from position.
CAUTION
24. Place the bearing spacer (27) onto
the face of the upper cover plate
(32). Position of undercut is
down. See FIGURE 73.
Install bearing spacer
25. Lightly grease roller thrust bearing
(28), and place it on the upper
cover plate (32), inside the bearing
spacer (27). See FIGURE 74.
Install bearing