10
HGF Series Service Procedure
Figure 6
Figure 5
Figure 4
Figure 3
2.
To avoid distorting or
damaging the HGF unit, do
not clamp it directly into a
vise. Clamp a service
assembly fixture described
in FIGURE 1 securely in a
vise, See FIGURE 3, and
place the HGF unit, input
shaft/wheel tube first, into
the service assembly fixture.
Attach the unit to the fixture
with four 5/16-24 UNF nuts.
See FIGURE 4.
Place HGF unit in
service fixture
NOTE: Before beginning the
disassembly of HGF unit, study the
relative positions of the alignment
grooves on the side of the components
in the assembly. Also, note the jacket
tube contact brush cover hole radial
position relative to the side of the unit
with the alignment grooves. The
relative alignment groove positions on
the components and the jacket tube
contact brush cover hole positions
must be maintained at reassembly.
Refer to the alignment groove graphic
on fold-out.
NOTE
3.
Loosen plug (6) or hex plug
(6A) assembly in the port
cover (2) for disassembly
after the port cover is
removed from the unit. Use
an appropriate type
screwdriver, T-30 Torx driver
or 7/8 inch hex socket. See
FIGURE 5.
Loosen plug assembly
4.
Remove the four retaining
nuts (1) from the port cover
(2) assembly. Be careful not
to damage the protruding
ports. See FIGURE 6.
Replace any nut that has
damaged threads or hex.
Remove port cover nuts