22
HGF Series Service Procedure
Figure 51
Figure 50
Figure 49
NOTE: If contact ring assemblies
and horn wires are not required,
go to assembly Step 6.
NOTE
4.
Install the contact ring
assembly(ies) (43), if required,
onto the input shaft/wheel tube
(33) into the same position as
before disassembly. See FIGURE
50.
Install contact ring
assembly
CAUTION: Failure to check the electrical
functions of the input shaft/wheel tube,
horn cable assembly before it is
assembled into the HGF unit, would
require another complete disassembly
of the unit if proved electrically defective
after the HGF unit is assembled.
CAUTION
5.
Insert horn cable assembly (47)
spade terminal end first into the
steering wheel end of the input
shaft/wheel tube (33) so that it
exits from the horn cable outlet
hole. Push the horn cable spade
terminal onto the contact ring (43)
terminal connector. Be sure it is a
good, firm connection. Position
the horn cable protector sleeve so
that it protects the horn cable from
any sharp corner where it exits the
horn cable outlet hole. Position
and fasten the contact ring
assembly (43) with screw (42).
Use about 1 1/2 turns of tape
around the input shaft/wheel tube,
horn cable and contact ring to hold
the horn cable in place. See
FIGURE 51. Check for electrical
continuity (connection) required
from horn cable assembly (47)
upper terminal to contact ring of
contact ring assembly (43). There
must not be electrical continuity
(connection) from upper horn
cable terminal or contact ring to
input shaft/wheel tube (33). Also,
see FIGURES 99 and 100.
Install horn cable
assembly
3.
Apply clean grease to bushing (38)
and stack upper cover and jacket
tube assembly (37) on the four
bolts (40) with the jacket tube
pointing down through the hole in
the fixture. Make sure the square
shoulder of the bolts engage the
square holes in the upper cover.
See FIGURE 49.
Stack upper cover and
jacket tube assembly
Содержание Hydraguide HGF Series