DMTLMX
Maximum Motor Inductance
Type
Motor
Syntax
<a_><!>DMTLMX<r>
(does not take effect until RESET, DRESET or cycle
power)
Units
r = mH (measured line-to-line)
Range
0.1 to 200.0 (motor dependent) : ±0.1
Default
0.0 (DMTLMX of 0 results in motor config. error)
Response
DMTLMX:
*DMTLMX10.0
See Also
DMTLMN, DMTR, TASX, TCS
Product Rev
GT6K n/a
GV6K 6.0
(applicable only to
servo axes)
NOTE
: This command does not take effect until you cycle power to the drive, or issue a
RESET
or
DRESET
command.
AUTO-SETUP
:
This command is automatically set according to the Parker motor selected with the
configuration utility in Motion Planner (see page
6
) . If you did not use the configuration utility or are not using
a Parker Motor, this command is set to zero and you will have to manually set this parameter. (Refer to
DMTR
for a list of auto-configured commands.) If the drive is powered up when this command is set to zero (for
instance, if
RFS
is executed), the drive reports a motor configuration error with
TASX
bit 7, writes a value of
-32714 to the
TCS
register, and shuts down the drive (
DRIVE0
).
The
DMTLMX
command specifies the maximum value of motor inductance. This will usually differ from the
nominal nameplate value since actual inductance is usually position dependent.
DMTMAX
Maximum Motor Winding Temperature
Type
Motor
Syntax
<a_><!>DMTMAX<r>
Units
r = Degrees Celsius
Range
-50.0 to 250.0 : ±0.1
Default
125.0
Response
DMTMAX:
*DMTMAX125.0
See Also
DMTAMB, DMTIC, DMTRWC, DMTTCM, DMTTCW, TASX
Product Rev
GT6K n/a
GV6K 6.0
(applicable only to
servo axes)
AUTO-SETUP
:
This command is automatically set according to the Parker motor selected with the
configuration utility in Motion Planner (see page
6
). If you did not use the configuration utility or are not using a
Parker Motor, you will have to manually set this parameter. (Refer to
DMTR
for a list of auto-configured
commands.)
The
DMTMAX
command sets the maximum motor winding temperature allowed. The
DMTMAX
value, in
conjunction with the motor thermal time constant (
DMTTCM
), the motor winding time constant (
DMTTCW
),
the motor thermal resistance (
DMTRWC
) and the continuous motor current (
DMTIC
), is used in a real-time
estimation of the motor winding temperature. When the winding temperature exceeds
DMTMAX
, the drive
faults and
TASX
bit #30 is set.
NOTE
: If you cycle power, or issue a
RESET
or
DRESET
command, the drive resets its motor thermal
model (in internal software). Be aware that your motor’s winding temperature may still be high.