12
Gemini GV6K/GT6K Command Reference
Programming Error Messages
(continued)
Error Response
Possible Cause
INVALID
CONDITIONS
FOR
COMMAND
System not ready for command (e.g.,
LN
command issued before the
L
command).
Following (these conditions can cause an error during Following):
•
The
FOLMD
value is too small to achieve the preset distance and still
remain within the
FOLRN/FOLRD
ratio.
•
A phase shift cannot be performed:
FSHFD
.... Error if already shifting or performing other time based move.
FSHFC
.... Error if currently executing a
FSHFD
move, or if currently
executing another
FSHFC
move in the opposite direction.
•
The
FOLEN1
command was given while a profile was suspended by a
GOWHEN
.
INVALID
CONDITIONS
FOR
S_CURVE
ACCELERATION—FIELD
n
Average (AA) acceleration or deceleration command (e.g.,
AA
,
ADA
,
HOMAA
,
HOMADA
, etc.) with a range that violates the equation ½A
≤
AA
≤
A (A is the
max. accel or decel command—e.g.,
A
,
AD
,
HOMA
,
HOMAD
, etc.)
INVALID
DATA
Data for a command is out of range.
Following (these conditions can cause an error during Following):
•
The parameter supplied with the command is valid.
FFILT
Error if: smooth number is not 0-4
FMCLEN
.. Error if: master steps > 999999999 or negative
FMCP
...... Error if: master steps > 999999999 or < -999999999
FOLMD
.... Error if: master steps > 999999999 or negative
FOLRD
.... Error if: master steps > 999999999 or negative
FOLRN
.... Error if: follower steps > 999999999 or negative
FSHFC
.... Error if: number is not 0-3
FSHFD
.... Error if: follower steps > 999999999 or < -999999999
GOWHEN
.. Error if: position > 999999999 or < -999999999
WAIT
...... Error if: position > 999999999 or < -999999999
•
Error if a
GO
command is given in the preset positioning mode (
MCØ
) and:
FOLRN
= zero
FOLMD
= zero, or too small
(see Following chapter in the
Programmer’s Guide
)
INVALID
FOLMAS
SPECIFIED
Following: An illegal master was specified in
FOLMAS
. A follower may never
use its own commanded position or feedback source as its master.
INVALID
RATIO
Following: Error if the
FOLRN:FOLRD
ratio after scaling is > 127 when a
GO
is
executed.
INVALID TASK IDENTIFIER
Attempting to launch a
PEXE
or
EXE
command into the supervisor task (task 0).
LABEL
ALREADY
DEFINED
Defining a program or label with an existing program name or label name.
MASTER
SLAVE
DISTANCE
MISMATCH
Attempting a preset Following move with a
FOLMD
value that is too small.
MAXIMUM
COMMAND
LENGTH
EXCEEDED
Command exceeds the maximum number of characters.
MAXIMUM
COUNTS
PER
SECOND
EXCEEDED
Velocity value is greater than 1,600,000 counts/sec.
MOTION
IN
PROGRESS
Attempting to execute a command not allowed during motion (see Restricted
Commands During Motion
section in the
Programmer's Guide
.)
Following: The
FOLEN1
command was given while that follower was moving in
a non-Following mode.
NEST
LEVEL
TOO
DEEP
IFs
,
REPEATs
,
WHILEs
, or
GOSUBs
nested greater than 16 levels
(for each type).