Gemini GV6K/GT6K Command Reference
[ DPTR ]
Data Pointer Location
Type
Data Storage; Assignment or Comparison
Syntax
see
below
Units
n/a
Range
n/a
Default
n/a
Response
n/a
See Also
[ DAT ], DATA, [ DATP ], DATPTR, DATSIZ, TDPTR
Product Rev
GT6K 6.0
GV6K 6.0
The
DPTR
command can be used to compare the current pointer location (the number of the data element to
which the data pointer is pointing) against another value or numeric variable, or to assign the pointer location
number to a variable. The current data pointer location is referenced to the current active data program
specified in the first integer of the last
DATSIZ
or
DATPTR
command.
Syntax:
VARn=DPTR
where “
n
” is the variable number,
or
DPTR
can be used in an expression such as
IF(DPTR=1)
Example
:
DATSIZ4,200
; Create data program called DATP4 with 200 data elements
DATPTR4,20,2
; Set the data pointer to data element #20 in DATP4 and set the
; increment to 2 (DATP4 becomes the current active data program)
VAR1=DPTR
; Assign the number of the pointer location in DATP4 to numeric
; variable #1
VAR1
; Response is *VAR1=20. Indicates that the data pointer is
; pointing to data element #20.
DPWM
Drive PWM Frequency
Type
Drive
Configuration
Syntax
<a_><!>DPWM <i>
(does not take effect until RESET, DRESET or cycle
power)
Units
kHz
Range
0, 8, 16, 20 or 40
Default
0 (use the drive’s default frequency):
GV6K-U3, GV6K-U6, GV6K-U12, GV6K-H20, GV6K-H40: 8 KHz
GV6K-L3: 40 KHz
Response
DPWM8
See Also
Product Rev
GT6K n/a
GV6K 6.0
(applicable only to
servo axes)
NOTE
: This command does not take effect until you cycle power to the drive, or issue a
RESET
or
DRESET
command.
Use the
DPWM
command to select the drive’s PWM frequency. This value is the internal PWM frequency as
seen at the motor windings; the motor ripple current is twice this frequency. In general, for a given drive
power level, the higher the switching frequency, the lower the motor ripple current heating and the lower
both the peak and continuous current ratings.
The table below lists the drive’s continuous current and peak current ratings for different PWM
frequencies.
CONTINUOUS
CURRENT PEAK
CURRENT
Drive Input
Voltage
DPWM8 DPWM16 DPWM20 DPWM40 DPWM8 DPWM16 DPWM20 DPWM40
GV6K-L3
120VAC, 1 phase
n/a n/a n/a 3.0A
n/a
n/a n/a 7.5A
GV6K-U3*
240VAC, 1 phase
3.0A n/a
n/a
n/a
7.5A
n/a n/a n/a
GV6K-U6*
240VAC, 1 phase
6.0A
4.5A
3.6A
n/a
15.0A 11.2A 9.0A
n/a
GV6K-U12*
240VAC, 1 phase
12.0A
9.0A
7.2A
n/a
20.0A
22.5A 18.0A n/a
GV6K-H20
240VAC, 1 phase
16.0A
13.0A
11.0A
n/a
50.0A
32.5A 27.5A n/a
GV6K-H20
240VAC, 3 phase
20.0A
13.0A
11.0A
n/a
50.0A
32.5A 27.5A n/a
GV6K-H40
240VAC, 1 phase 23.1A
23.1A 22.0A n/a
100.0A
65.0A 55.0A n/a
GV6K-H40
240VAC, 3 phase 40.0A
26.0A 22.0A n/a
100.0A
65.0A 55.0A n/a
* Current Ratings are the same for 120VAC operation
Note: All currents are peak of the sine wave values