Command Descriptions
321
* Bit #31: failed
PCOMP
compile is cleared on power up,
RESET
, or after successful compile. Possible causes include:
•
Errors in profile design (e.g., change direction while at non-zero velocity; distance & velocity equate to < 1 count
per system update; preset move profile ends in non-zero velocity)
•
Profile will cause a Following error (see
TFSF
,
TFS
, or
FS
command descriptions)
•
Out of memory (see
TSS
bit #30)
•
Axis already in motion at the time of the
PCOMP
command
•
Loop programming errors (e.g., no matching
PLOOP
or
PLN
; more than 4 embedded
PLOOP
/
PLN
loops)
•
PLCP
program contains invalid commands.
TSSF
Transfer System Status (full-text report)
Type
Transfer
Syntax
<a_><!><%>TSSF
Units
n/a
Range
n/a
Default
n/a
Response
TSSF:
(see example below)
See Also
PORT, [ SS ], TAS, TCMDER, TRGFN, TSS, TSTAT
Product Rev
GT6K 6.0
GV6K 6.0
The
TSSF
command returns a text-based status report. This is an alternative to the binary report (
TSS
).
MULTI-TASKING
If you are using multi-tasking, be aware that each task has its own system status register.
Therefore, to check a specific task’s system status, you must prefix the
TSSF
command
with the task identifier (e.g.,
2%TSSF
to check system status for Task 2). If no task
identifier is given, the
TSSF
response is for the task supervisor (Task 0).
Example
TSSF
response:
*TSSF
*System Ready YES Thumbwhl Data Load NO
*RESERVED NO Ext Prog Sel Mode NO
*Program Executing NO Time Command NO
*Immediate Comm Last NO Waiting RP240 Data NO
*
*ASCII Mode YES RP240 Connected NO
*Echo Mode YES Memory Error NO
*Defining a Program NO Servo Data Transfer NO (RESERVED for GT6K)
*Trace Mode NO Suspended on Swap NO
*
*Step Mode NO RESERVED NO
*FS Translate Mode NO Suspended on COM1 NO
*Command Error NO Suspended on COM2 NO
*Break Point Active NO Program Pending NO
*
*Pause Active NO Comp Mem Near Full NO
*Wait Active NO Compiled Mem Full NO
*Checking On Conds NO Compile Error NO
*Waiting for Data NO EXE Failed NO