Command Descriptions
67
values of
VAR1
through
VAR4
will be assigned respectively to the first four data elements in the data
program and the pointer will stop at data element #5. The response to the
TPROG
DATP1
command would
be as follows (the text is highlighted to illustrate the location of the data pointer after the
DATTCH1,2,3,4
command is executed).
*DATA=2.Ø,4.Ø,8.Ø,64.Ø
*DATA=
Ø.Ø
,Ø.Ø,Ø.Ø,Ø.Ø
*DATA=Ø.Ø,Ø.Ø,Ø.Ø,Ø.Ø
*DATA=Ø.Ø,Ø.Ø,Ø.Ø
Example:
Refer to the
DATSIZ
command
.
DAUTOS
Auto Current Standby
Type
Drive Configuration
Syntax
<a_><!>DAUTOS<r>
Units
r = percent reduction of motor current
Range
0.00-99.99 : ±0.01
Default
0.00 (no current reduction)
Response
DAUTOS *DAUTOS0
See Also
Product Rev
GT6K 6.0
GV6K n/a
(applicable only to
stepper axes)
The
DAUTOS
command allows you to let the motor cool when it is not moving. When automatic current
standby is set to a value other than 0.00 (default), the motor current will be reduced by that percentage
when the drive has not issued a motion command for one second. Full commanded current is restored upon
the first motion command that the drive issues.
WARNING
: Motor torque is reduced when the motor current is reduced. Applications with vertical loads
or loads that require holding torque at zero speed should not use this feature.
DCLEAR
Clear Display
Type
Display (RP240) Interface
Syntax
<a_><!>DCLEARi
Units
n/a
Range
i
=
0
(clear
all
lines),
1
(clear
line
1),
or
2
(clear
line
2)
Default
n/a
Response
n/a
See Also
DLED, DPASS, DPCUR, DSTP, DVAR, DVARB, DVARI, DWRITE
Product Rev
GT6K 6.0
GV6K 6.0
The Clear Display (
DCLEAR
) command clears lines (as specified with
i
) of the RP240 display. After clearing a
line, the cursor will be reset to the beginning of that line (or to the beginning of line 1 if all lines are cleared).
DCLRLR
Clear the Latched Status Register Bits
Type
Drive
Configuration
Syntax
<a_><!>DCLRLR
Units
n/a
Range
n/a
Default
n/a
Response
n/a
See Also
DMODE, DMTLIM, DMVLIM, DIFOLD, TASX, TTRQ
Product Rev
GT6K 6.0
GV6K 6.0
TASX
status register bits 18, 19, 20 and 31 (see descriptions below) indicate conditions in which drive
protective software has engaged, but drive operation continues. These status bits remain set (
latched
),
regardless of whether the conditions persist, and are cleared with the
DCLRLR
command or when you issue
a
RESET
or
DRESET
command, cycle power, or activate the Reset input.