SECTION 3 – MACHINE CONTROLS, INDICATORS AND OPERATION
3-40
– JLG Lift–
E-0-0-8
Battery temperature is out of range
Possible battery temperature sensor error. Check temperature sensor and connections.
Reset charger. This error will automatically clear once the condition has been corrected.
E-0-1-1
Charger is disabled by external command
This error will only appear in the charger’s log files, not on the user interface. It indicates that
the charger has been disabled by an external controller over the CAN bus network (Comm
configuration only).
E-0-1-2
Reverse polarity error
Battery is connected to the charger incorrectly. Check the battery connections. This error will
automatically clear once the condition has been corrected.
E-0-1-6
E-0-1-8
E-0-2-6
USB operation failed
Software upgrade failure or script operation failure. Ensure the USB flash drive is properly
formatted and retry inserting the USB flash drive into the charger.
E-0-1-7
USB operation failed
Remove and reinsert the USB drive. If condition persists, cycle AC and retry by reinserting
the USB drive.
E-0-1-9
Hardware does not support software
The charger does not support the new software version. Contact your Distributor / Product
Support.
E-0-2-3
High AC voltage error (>270VAC)
Connect charger to an AC source that provides stable AC between 85 - 270 VAC / 45-65 Hz.
This error will automatically clear once the condition has been corrected.
E-0-2-4
Charger failed to initialize
The charger has failed to turn on properly. Disconnect AC input and battery for 30 seconds
before retrying.