![Oshkosh Corporation JLG TOUCAN 10E Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/oshkosh-corporation/jlg-toucan-10e/jlg-toucan-10e_operation-and-safety-manual_1655759051.webp)
SECTION 3 – MACHINE CONTROLS, INDICATORS AND OPERATION
– JLG Lift –
3-9
1. 5 Amp. Circuit Breaker
- This circuit breaker protects
the control circuit in case of a short circuit or other
malfunction.
2. Overload Warning Light
- This lamp (red), when
blinking, indicates that the maximum rated load in the
platform is exceeded. The platform must be safely
unloaded until the alarm stops.
3. Multi-Display Indicator (MDI)
Hourmeter - The hourmeter symbol is lit when the
number of operated hours is displayed.
Speed reduction - Indicates that the maximum
drive speed is reduced when the platform is out of
transport position.
The wrench symbol is lit when a DTC (Diagnosis
Troubleshooting Code) is displayed.
Five Digits Display
In normal operating condition, displays the total
amount of machine operation time accumulated.
In abnormal operating condition, displays a DTC
(Diagnosis Troubleshooting Code).
Alarm LED
Illuminates in abnormal operating condition (when
a DTC, other than 00xx DTC’s exists).
Battery Discharge Indicator (BDI).
This bar-graph is designed to let the operator know
the condition of the battery before starting to use
the machine.
The last bar flashes when the level of charge is less
than 10%. The bar-graph is not displayed when the
batteries are completely discharged.
To