SECTION 5 – GENERAL SPECIFICATIONS AND MAINTENANCE
5-50
– JLG Lift–
226
ACCELERATOR FAULTY -
WIPER OUT OF RANGE
The joystick wiper signal input is outside the
acceptable voltage range.
• Center joystick and check to see if a power cycle will clear DTC.
Refer problem to a qualified JLG mechanic.
227
STEER SWITCHES FAULTY
The steer left and steer right inputs were closed
simultaneously.
• Check if the steer switches are damaged, obstructed or
jammed.
Refer problem to a qualified JLG mechanic.
228
FUNCTION LOCKED OUT -
ACCELERATOR NOT
CENTERED
The joystick was not centered at power-up in plat
-
form mode.
• Release joystick and allow to center.
• Check if the joystick is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
229
FUNCTION PROBLEM -
TRIGGER PERMANENTLY
CLOSED
The trigger switch was closed during power-up in
platform mode.
• Check if the trigger switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
2210
TRIGGER CLOSED TOO LONG
WHILE IN NEUTRAL
The trigger switch was closed for more than
seven seconds while the joystick was centered.
• Check if the trigger switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
2233
FUNCTION ENABLE RELAY -
INVALID SIGNAL
There is a problem with the Function Enable Relay.
Refer problem to a qualified JLG mechanic.
2240
LIFT ENABLE SWITCH
PERMANENTLY SELECTED
The Lift Enable Switch was closed during power-
up in platform mode.
• Check if the lift enable switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
2241
LIFT ENABLE SWITCH
PERMANENTLY SELECTED
The Lift Enable Switch was closed during power-
up in platform mode.
• Check if the lift enable switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
To
order
go
to
Discount-Equipment.com