SECTION 5 – GENERAL SPECIFICATIONS AND MAINTENANCE
5-16
– JLG Lift–
Battery Voltage
NOTE:
Voltage measures must be done after a complete charge, once the charger has
been unplugged and after the battery has been standing for at least 15 min
-
utes.
- Measure the cell voltage from B+ (Red Cable) to B- (Blue cable)
and record the value in the battery service log.
NOTE:
If important disparities are noticed between voltage of different cells contact
JLG Product Support.
Use of a Battery in a Cold Environment
Low temperatures decrease battery capacity. The battery
must be fully charged when the machine is operated in a cold
environment.
Battery Not Working Continuously or Inactive Battery
A battery that is not used or used intermittently must be
stored charged in a dry area away from freezing tempera
-
tures. A charge must be performed once a month.
- Disconnect the battery to insulate it electrically.
- Keep the top of the battery clean and dry to prevent self-dis
-
charge.
IF THE B ATTERY IS N OT U SED CON TINU OUSL Y, IT MUST B E
RECHARGED BEFORE USE AND AT LEAST ONCE A MONTH.
BEFORE RETURNING TO SERVICE A BATTERY THAT REMAIN INACTIVE
FOR A LONG PERIOD OF TIME, CHARGE THE BATTERY AND CHECK
VOLTAGE OF EACH CELL.
To
order
go
to