![Oshkosh Corporation JLG TOUCAN 10E Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/oshkosh-corporation/jlg-toucan-10e/jlg-toucan-10e_operation-and-safety-manual_1655759142.webp)
SECTION 5 – GENERAL SPECIFICATIONS AND MAINTENANCE
– JLG Lift –
5-49
2-1 Power-Up
2-2 Platform Controls
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
211
POWER CYCLE
The normal help message is issued at each power
cycle. Displays on the analyzer only.
Normal operation. No check necessary.
212
KEYSWITCH FAULTY
Both Platform and Ground Modes are selected
simultaneously. Defaults to Ground Mode.
Refer problem to a qualified JLG mechanic.
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
221
FUNCTION PROBLEM - HORN
PERMANENTLY SELECTED
The horn switch was closed during power-up in
platform mode.
• Check if the horn switch is damaged, obstructed or jammed.
Refer problem to a qualified JLG mechanic.
224
FUNCTION PROBLEM - STEER
LEFT PERMANENTLY
SELECTED
The Steer Left Switch was closed during power-
up in platform mode.
• Check if the steer left switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.
225
FUNCTION PROBLEM - STEER
RIGHT PERMANENTLY
SELECTED
The Steer Right Switch was closed during power-
up in platform mode.
• Check if the steer right switch is obstructed or jammed.
Refer problem to a qualified JLG mechanic.