7 Teaching pendant operation
−
58
−
7.6 I/O
checking
The I/O check function is used to check input signals from the sensors and host controller or output signals to
the host controller for testing purposes.
Perform I/O check to examine the wiring condition after the equipment has been started or during inspection.
Note
All I/O functions and operations are disabled during the I/O check. Nothing occurs even
after turning ON any I/O signal.
1.
On the first screen of the TST mode, press the
[F2] key to select I/O check.
2.
Press one of [F2] to [F4] keys.
Use the
[
↑
] [
↓
]
keys to move through the items on
the applicable check screen selected by pressing one
of
[F2]
to
[F4]
keys.
•
Input signals
Input signals can be monitored.
ON: “
∗
”
OFF: “
•
”
•
Output signals
Switch the ON/OFF status of each output signal by pressing
the
[F4]
key.
ON: “
∗
”
OFF: “
•
”
•
A-phase pulse output (ASG), B-phase pulse
output (BSG)
1000 pulses (1000 Hz) are output every time the
[F4]
key is
pressed.
Pulse is output: “
∗
”
Pulse is stopped: “
•
”