3 Connection
−
24
−
3.7 Connecting the battery
If the controller is used in the absolute mode, be sure to connect an optional battery
PAEZ-BT2
(sold separately).
Installing the battery
The battery has a built-in protective circuit. Use the supplied battery holder to secure the battery.
•
Battery installation dimensions
2×M4
13±0.3 mm
(0.512±0.012 in.)
Connecting and removing the battery
Connect the battery to the controller and input the logic power supply. The battery will start charging. The
battery will be fully charged in around 48 hours [assuming an ambient temperature of 20
°
C (68 °F)].
Cut off the logic power supply to the controller before removing the battery
ESMC-A2
or
ESMC-C2
from the
controller.
•
Pin assignments of battery connector
Battery power ground
Battery power input
Note
•
The product is shipped with an uncharged battery. Always charge the battery before use.
•
When turning off the logic power supply or turning it on again, do not move the moving
part of the motorized actuator. It will disable accurate monitoring of the moving part.
•
Data is retained for approx. 15 days. If the power will not be supplied to the controller
for more than 15 days, remove the battery. If the battery is kept in the controller for a
longer period, battery fluid may leak or battery performance may drop.
•
Once the battery is removed, the current position is cleared. If you have replaced the
battery, be sure to perform a return-to-home operation.