8-2
Section
CPM2A/CPM2C Cycle Time and I/O Response Time
532
Code
OFF execution time (
µ
s)
Conditions (Top: min.; bottom: max.)
ON execution
time (
µ
s)
Mnemonic
63
CTBL
186.0
Registering a target value comparison table and
starting comparison in incrementing/decrement-
ing pulse input mode via word
2.6
807.5
Registering a target value comparison table and
starting comparison in incrementing/decrement-
ing pulse input mode via
DM
185.8
Registering a target value comparison table and
starting comparison in incrementing mode via
word
781.9
Registering a target value comparison table and
starting comparison in incrementing mode via
DM
410.0
Registering a range comparison table and start-
ing comparison in incrementing/decrementing
pule input mode via word
418.9
Registering a range comparison table and start-
ing comparison in incrementing/decrementing
pule input mode via
DM
380.6
Registering a range comparison table and start-
ing comparison in incrementing mode via word
399.7
Registering a range comparison table and start-
ing comparison in incrementing mode via
DM
183.4
Only registering a target value comparison table
in incrementing/decrementing pulse input mode
via word
810.3
Only registering a target value comparison table
in incrementing/decrementing pulse input mode
via
DM
182.4
Only registering a target value comparison table
in incrementing mode via word
776.3
Only registering a target value comparison table
in incrementing mode via
DM
351.0
Only registering a range comparison table in
incrementing/decrementing pule input mode via
word
359.1
Only registering a range comparison table in
incrementing/decrementing pule input mode via
DM
331.2
Only registering a range comparison table in
incrementing mode via word
335.9
Only registering a range comparison table in
incrementing mode via
DM
64
SPED
44.6
Specifying a constant in independent mode
2.6
53.8
Specifying
DM in independent mode
42.9
Specifying a constant in continuous pulse out-
put mode
52.0
Specifying
DM in continuous pulse output
mode
34.1
Specifying a word when changing output fre-
quency
39.8
Specifying
DM when changing output fre-
quency