2-5
Section
CPM2A/CPM2C Pulse Output Functions
115
Note
The following examples are for Fujitsu-compatible connectors. I/O bit addresses
and connector pin numbers depend on the models. Refer to the
CPM2C Opera-
tion Manual
(W356) or the
CPM2C-S Operation Manual
(W377) for details.
Motor Driver
24 VDC
Thumbwheel switch
Input connector
Output connector
(See above note.)
Note
Refer to the operation manual for details on wiring.
PC Setup
High-speed counter not used.
(Set for other than synchronized pulse control.)
DM 6642
0
0
15
0
Programming (CPM2A Example)
00005 (Execution condition)
Detects turning OFF of execution condition.
Stops pulse output 0.
Changes analog control 0 value to a value from 0 to 100.
Value in SR 250 (Analog control 0 in CPM2A PCs) (see note)
Divide value by 2.
Duty ratio setting
Pulse outputs with variable duty
Pulse output 0
Output frequency: 100 Hz
Duty ratio setting
DIV(33)
PWM(––)
INI(61)
(14)
Note
The CPM2C is not provided with
an analog control. For external
settings, specify the input word
connected to the thumbwheel
switch.