3-2
Section
Temperature Sensor Units
199
Note
1. Turn OFF the power supply before changing the temperature range setting.
2. Do not touch the DIP switch or rotary switches while power is turned ON.
Static electricity may cause malfunctions.
The rotary switch is used to set the temperature range.
Caution
Set the temperature range according to the type of temperature sensor con-
nected to the Unit. Temperature data will not be converted correctly if the tem-
perature range does not match the sensor.
Caution
Do not set the temperature range to any values other than those for which tem-
perature ranges are given in the following table. An incorrect setting may cause
operating errors.
Setting
CPM1A-TS001/002
CPM2C-TS001
CPM1A-TS101/102
CPM2C-TS101
Input
type
Range
(
°
C)
Range
(
°
F)
Input
type
Range
(
°
C)
Range
(
°
F)
0
K
–200 to
1,300
–300 to
2,300
Pt100
–200.0 to
650.0
–300.0 to
1,200.0
1
0.0 to
500.0
0.0 to
900.0
JPt100
–200.0 to
650.0
–300.0 to
1,200.0
2
J
–100 to
850
–100 to
1,500
---
Setting not possible
3
0.0 to
400.0
0.0 to
750.0
---
4 to F
---
Setting not possible
---
Rotary Switch Setting