Also, muting sensors and F3SG-RA must be installed so that muting state caused by a workpiece
should be ended before the next workpiece arrives at the first muting sensor.
Timing Chart
Workpiece
Workpiece
Workpiece
Workpiece
F3SG-RA
A1 B1
F3SG-RA
A1 B1
Hazardous zone
Hazardous zone
d2
d1
d2
d1
Moving direction
Moving direction
T2 max.
80 ms max.
T5 max.
Muting input A
(Muting sensor A1)
ON
OFF
Muting input B
(Muting sensor B1)
Beam state
Unblocked
Blocked
OSSD
ON
OFF
ON
OFF
Muting state
Enabled
Disabled
T1max
T4 (1 s)
T1min to T1max
T3 (0.1 s) max.
T3(1 s) max.