199
F3SG-R
User’s Manual
Ch
apt
e
r
5
Wir
ing
Ex
amples
(F3
S
G-
RA
Series
)
Input/Output Circuit and Applications
E
5-2-2-4. Standard Muting Mode with four Muting Sensors using PNP Outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output
and External Test in 24 V Active.
[DIP Switch settings] *5
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
[Wiring Example]
Function
DIP-SW1
DIP-SW2
Receiver
EDM Disabled (factory default setting)
Auto Reset (factory default setting)
PNP (factory default setting)
Emitter
External Test: 24 V Active (factory default setting)
㻞
㻻㻺
㻞
㻻㻺
㻟
㻻㻺
㻟
㻻㻺
㻠
㻻㻺
㻠
㻻㻺
㻣
㻻㻺
㻣
㻻㻺
㻠
㻻㻺
OSSD1 : Bla
ck
OSSD2 : White
2
4
VD
C
: Br
own
Not used : Yell
ow
TEST : Bla
c
k
Not used : W
h
ite
2
4
VD
C
: Br
own
0 VDC : Blu
e
Receiver
Emitter
0 V
D
C : B
lu
e
AU
X : Red
MUTE B
: Pink
MUTE A
: Gray
RE
SET : Yell
ow
*1
S1: Test Switch (Connect the line to 0 V if this
switch is not required)
S2: Lockout/Interlock Reset Switch,
Override Switch or Override Cancel Switch
A1, A2, B1, B2: Muting sensor
S1
S2
*2
Muting
Sensor
(PNP
output)
Reflector
F3SG
F3SG
A1
A2
B1
B2
Power Supply
+24 VDC
0 VDC
Safety
Controller *3 *4
IN1
IN2
Unblocked
Blocked
MUTE A
Beam state
MUTE B
OSSD
Test Switch (S1)
F39-JG
A-L
F39-JG
A-D
PLC *6
IN
*1. Also used as Override input line.
*2. Make sure to connect an override cancel switch to the Reset line when
using the override function. Otherwise the override state may not be
released by the override cancel switch, resulting in serious injury.
5-4. Connectable Safety Control Units
for more information.
*4.The safety controller and the F3SG-R must share the power supply or
be connected to the common terminal of the power supply.
*5. The functions are configurable with DIP Switch. Refer to
for more information on setting the functions
by the DIP Switch.
*6. When connecting to the PLC, the output mode must be changed with
the Configuration Tool according to your application.
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...