Dynamic Muting Allowable Beam
The dynamic muting allowable beam allows the muting zone measured by the Zone Measurement to
be expanded by the number of additional beam(s) specified as allowable beam.
Timing chart
2-12-5. Factory Default Setting
In the factory default setting, the muting mode is set to Standard Muting Mode and the dynamic muting
to Disable.
2-12-6. Setting with DIP Switch
If the pre-reset function is enabled by the DIP Switch, the muting function is disabled.
Otherwise the muting function is always being enabled.
Refer to
Chapter 3 Setting with DIP Switch
for more information on setting this function by the DIP Switch.
2-12-7. Setting with Configuration Tool
Some settings of functions configurable with the Configuration Tool may increase risks.
Make sure the Responsible Person conduct a thorough risk assessment analysis before
managing and changing the settings. Unintended changes to the settings may cause a
person to go undetected, resulting in serious injury.
The user can make changes to the settings by the Configuration Tool.
*Setting parameters of the following functions can be saved according to the states where the Muting function is
enabled and disabled, respectively. After changing the Muting function from Enable to Disable or from Disable to
Enable, also check the settings of these functions again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary Output, Lamp
Output
Function
Factory Default Setting
Available Parameters
Muting function *
Enable
Enable/Disable
Muting mode
Standard muting mode
Standard muting mode/Exit-only muting
mode/Position detection muting mode
Statistics data recording
Enable
Enable/Disable
ON
OFF
Muting Input A
Muting State
ON
OFF
ON
OFF
Enabled
Disabled
Zone Measurement
Beam state
Unblocked
Blocked
Partial Zone
Tdyn (3 s)
All Zone
Muting Input B
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...