10
Chapter
1
LED Indica
tor
s
F3SG-R
User’s Manual
Overview and Specifications
1-4-1. LED Indicator Status
Shown below are indication statuses of F3SG-R LED indicators when you purchased.
Emitter
Receiver
Location
Name of Indicator
Color
F3SG-RA
Series
F3SG-RE
Series
Illuminated
Blinking
1
Test
TEST
Green
X
-
External Test is being
performed
2
Operating range
LONG
Green
X
X
Long range mode is
selected
Lockout state due to DIP
Switch setting error or
Operating range selection
setting error
3
Power
POWER
Green
X
X
Power is ON.
Error due to noise
4
Lockout
LOCKOUT Red
X
X
-
Lockout state due to error
in emitter
Location
Name of Indicator
Color
F3SG-RA
Series
F3SG-RE
Series
Illuminated
Blinking
1
Top-beam-state
TOP
Blue
X
X
The top beam is
unblocked
Muting/Override state, or
Lockout state due to Cap
error or Other sensor error
*3
2
PNP/NPN mode
NPN
Green
X
NPN mode is selected by
DIP Switch
-
3
Response time
SLOW
Green
X
Response Time
Adjustment is enabled
-
4
Sequence error
SEQ
Yellow
X
-
Sequence error in Muting
or Pre-reset mode
5
Blanking
BLANK
Green
X
Blanking, Warning Zone
or Reduced Resolution is
enabled
Teach-in mode, or
Blanking Monitoring error
6
Configuration
CFG
Green
X
-
Teach-in mode, zone
measurement beng
performed by Dynamic
Muting, or Lockout state
due to Parameter error or
Cascading Configuration
error
7
Interlock
INT-LK
Yellow
X
Interlock state
Pre-reset mode *2
8
External device
monitoring
EDM
Green
X
RESET input is in ON
state *1
Lockout state due to EDM
error
9
Internal error
INTERNAL Red
X
X
-
Lockout state due to
Internal error, or error due
to abnormal power supply
or noise
10
Lockout
LOCKOUT Red
X
X
-
Lockout state due to error
in receiver
11
Stable-state
STB
Green
X
X
Incident light level is
170% or higher of ON-
threshold
Safety output is
instantaneously turned
OFF due to ambient light
or vibration
12
ON/OFF
ON/OFF
Green
X
X
Safety output is in ON
state
-
Red
Safety output is in OFF
state, or the sensor is in
Setting state
Lockout state due to
Safety Output error, or
error due to abnormal
power supply or noise
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...