201
F3SG-R
User’s Manual
Ch
apt
e
r
5
Wir
ing
Ex
amples
(F3
S
G-
RA
Series
)
Input/Output Circuit and Applications
E
5-2-2-6. Exit-Only Muting Mode with F3W-MA (L-Shaped Configuration with
4-Joint Plug/Socket Connector)
The following is the example of F3SG-RA with Scan Code A, External Device Monitoring disabled,
Auto Reset mode, PNP output and External Test in 24 V Active, and F3W-MA with Scan Code B,
Chattering and Void Space Prevention 1, Off-Delay 100 ms and Muting Enable enabled.
[DIP Switch settings]*1
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
[Wiring Example]
Function
DIP-SW1
DIP-SW2
F3SG-RA
Receiver
Scan Code A (factory default setting)
EDM Disabled (factory default setting)
Auto Reset (factory default setting)
PNP (factory default setting)
Emitter
Scan Code A (factory default setting)
-
External Test: 24 V Active (factory default setting)
-
F3W-MA
Receiver
Scan Code B (factory default setting)
*2
Chattering and Void Space Prevention 1
*2
*2
Off-Delay 100 ms
*2
*2
Muting Enable Enabled
*2
Emitter
Scan Code B (factory default setting)
-
㻝
㻻㻺
㻝
㻻㻺
㻞
㻻㻺
㻞
㻻㻺
㻟
㻻㻺
㻟
㻻㻺
㻠
㻻㻺
㻠
㻻㻺
㻣
㻻㻺
㻣
㻻㻺
㻝
㻻㻺
㻠
㻻㻺
㻝
㻻㻺
㻝
㻻㻺
㻞
㻻㻺
㻟
㻻㻺
㻞
㻻㻺
㻟
㻻㻺
㻠
㻻㻺
㻡
㻻㻺
㻠
㻻㻺
㻡
㻻㻺
㻢
㻻㻺
㻢
㻻㻺
㻝
㻻㻺
F3W-MA Receiver
(Primary)
F39-JG
□
A-D
F3SG-RA R
ece
iver
F3W-MA Emitter
(Primary)
F39-JG
□
A-L
F3SG-RA Emitter
24
VDC
:
Brown
OSSD 2:
White
OSSD 1:
Black
AUX:
Red
0 VDC
:
Blue
Reset:
Yellow *3
Muting Enable:
Gray
No
t u
s
ed:
Pink
No
t u
s
ed:
Yellow
No
t u
s
ed:
White
0 VDC
:
Blue
24
VDC
:
Brown
TEST:
Black
Safety
Controller *5 *6
IN1
IN2
+24 VDC
0 VDC
Power Supply
S2
S3
*4
S1
F39-GCN4-L
F39-GCN4-D
PLC *7
IN
S1: Test Switch (Connect the line to 0 V if this switch is not required)
S2: Lockout/Interlock Reset Switch, Override Switch or Override Cancel Switch
S3: Muting Enable Switch
ML: Muting lamp
*1. The functions are configurable with DIP Switch. For the DIP Switch of the F3SG-RA, refer to the
Chapter 3 Setting with DIP Switch
For the DIP Switch of the F3W-MA, refer to the
Smart Muting Actuator F3W-MA Series User's Manual
.
*2. DIP Switch Bank 2 of F3W-MA receiver is not used.
*3. Also used as Override input line.
*4. Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state may
not be released by the override cancel switch, resulting in serious injury.
*5. Refer to
5-4. Connectable Safety Control Units
for more information.
*6. The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power supply.
*7. When connecting to the PLC, the output mode must be changed with the Configuration Tool according to your application.
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...