196
Ch
apt
e
r
5
Wir
ing
Ex
amples
(F3
S
G-
RA
Series
)
F3SG-R
User’s Manual
Input/Output Circuit and Applications
5-2-2. Muting using PNP Outputs
5-2-2-1. Standard Muting Mode/Exit-Only Muting Mode using PNP Outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output
and External Test in 24 V Active.
[DIP Switch settings] *6
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
[Wiring Example]
Function
DIP-SW1
DIP-SW2
Receiver
EDM Disabled (factory default setting)
Auto Reset (factory default setting)
PNP (factory default setting)
Emitter
External Test: 24 V Active (factory default setting)
㻞
㻻㻺
㻞
㻻㻺
㻟
㻻㻺
㻟
㻻㻺
㻠
㻻㻺
㻠
㻻㻺
㻣
㻻㻺
㻣
㻻㻺
㻠
㻻㻺
OSSD1 : Black
OSSD2 : White
24 VDC : Brown
Not used : Yellow
TEST : Black
Not used : White
24 VDC : Brown
0 VDC
: Blue
Receiver
Emitter
0 VDC
: Blue
AUX : Red
MUTE B : Pink
MUTE A : Gray
RESET : Yellow *1
S1: Test Switch (Connect the line to 0 V if this switch
is not required)
S2: Lockout/Interlock Reset Switch,
Override Switch
or Override Cancel Switch
S2
*2
F39-JG
A-L
F39-JG
A-D
S1
Power Supply
+24 VDC
0 VDC
Safety
Controller *3 *4
Muting
Actuator *5
IN1
IN2
Unblocked
Blocked
MUTE A
MUTE B
OSSD
Test Switch (S1)
Beam state
PLC *7
IN
*1. Also used as Override input line.
*2. Make sure to connect an override cancel switch to
the Reset line when using the override function.
Otherwise the override state may not be released by
the override cancel switch, resulting in serious injury.
5-4. Connectable Safety Control Units
more information.
*4. The safety controller and the F3SG-R must share
the power supply or be connected to the common
terminal of the power supply.
*5. Refer to
Smart Muting Actuator F3W-MA Series
User's Manual
for more information.
*6. The functions are configurable with DIP Switch.
Refer to
Chapter 3 Setting with DIP Switch
for more
information on setting the functions by the DIP
Switch.
*7. When connecting to the PLC, the output mode must
be changed with the Configuration Tool according to
your application.
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...