• Tm: Machine's response time (s)
• Ts: Response time of the F3SG-R from ON to OFF (s)
• a: Height of machine hazardous zone (mm)
• b: Height of upper edge of detection zone (mm)
When Tm = 0.05 s, Ts = 0.008 s, a = 1,400 mm, b = 1,500 m:
From the table above, Cro = 850 mm. Since b is between 1,400 mm and 1,600 mm, b = 1,400
mm which has the greater Cro value, shall be used.
S = 2,000 mm/s × (0.05 s + 0.008 s) + 850 mm
= 966 mm
Since 966 mm is greater than 500 mm, use K = 1,600 mm/s and recalculate it.
S = 1,600 m/s × (0.05 s + 0.008 s) + 850 mm
= 942.8 mm
Since S = 942.8 mm is greater than S = 116 mm calculated by the calculation example of
Detection Zone Orthogonal to Direction of Approach
, the required safety distance S is 942.9 mm.
Detection Zone Orthogonal to Direction of Approach
Formulas according to ISO 13855/EN ISO 13855
.
Detection Zone Parallel to Direction of Approach
Use K = 1,600 mm/s and C = (1200 - 0.4 x H) in
formula (1) for calculation. Note that C must not be
less than 850 mm.
S = 1,600 mm/s x (Tm + Ts) + 1200 - 0.4 x H
• S = Safety distance (mm)
• Tm = Machine's response time (s)
• Ts = Response time of F3SG-R from ON to OFF
(s)
• H = Installation height (mm)
Note that H must satisfy:
1000 >= H >= 15 (d - 50 mm)
Also, you must include a hazardous condition under which a person may go through under a detection
zone if H exceeds 300 mm (200 mm for other purpose than industrial use) into risk assessment.
[Calculation example]
When Tm = 0.05 s, Ts = 0.08 s, and d = 14 mm:
S = 1,600 mm/s x (0.05 s + 0.08 s) + 1200 - 0.4 x 500 mm
= 1092.8 mm
When a warning zone is configured as in the figure, you must calculate L, a distance from an end of
casing to a detection zone, using a formula below:
L = (Total number of F3SG-R beams - number of warning zone beams - 1) x P + 10
+
Safety distance (S)
Hazard
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...