12
Chapter
1
Ra
tings
/Sp
ecif
ic
a
tion
s
F3SG-R
User’s Manual
Overview and Specifications
1-5. Ratings
/
Specifications
The
in the model names indicate the protective heights in millimeters.
F3SG-4RA
-14
F3SG-2RA
-14
F3SG-4RA
-30
F3SG-2RA
-30
F3SG-4RE
14
F3SG-2RE
14
F3SG-4RE
30
F3SG-2RE
30
Type of ESPE
(IEC 61496-1)
Type 4
F3SG-4RA
-14/-30
F3SG-4RE
14/30
Type 2
F3SG-2RA
-14/-30
F3SG-2RE
14/30
Performance
Object Resolution
(Detection Capability)
Opaque objects
14-mm dia.
30-mm dia.
14-mm dia.
30-mm dia.
Beam Gap
10 mm
20 mm
10 mm
20 mm
Number of Beams
15 to 207
8 to 124
15 to 207
8 to 124
Lens Size
5.2 × 3.4 (W × H) mm
7-mm dia.
5.2 × 3.4 (W × H) mm
7-mm dia.
Protective Height
160 to 2080 mm (6.3 to
81.9 inch)
190 to 2510 mm (7.3 to
98.7 inch)
160 to 2080 mm (6.3 to
81.9 inch)
190 to 2510 mm (7.3 to
98.7 inch)
Operating Range
Long
0.3 to 10.0 m (1 to 32 ft.) 0.3 to 20.0 m (1 to 65 ft.) 0.3 to 10.0 m (1 to 32 ft.) 0.3 to 20.0 m (1 to 65 ft.)
Short
0.3 to 3.0 m (1 to 10 ft.)
0.3 to 7.0 m (1 to 23 ft.)
0.3 to 3.0 m (1 to 10 ft.)
0.3 to 7.0 m (1 to 23 ft.)
Response Time
ON to OFF
Normal mode: 8 to 18 ms *1
Slow mode: 16 to 36 ms *1 *2
5 to 15 ms
OFF to ON 40 to 90 ms *1
25 to 75 ms
*1. Response time when used in one segment system or in cascaded connection.
Refer to
*2. Selectable by Configuration Tool.
Effective Aperture
Angle (EAA) (IEC
61496-2)
Type 4
±2.5° max., emitter and receiver at operating range of 3 m or greater
Type 2
±5.0° max., emitter and receiver at operating range of 3 m or greater
Light Source
Infrared LEDs, Wavelength: 870 nm
Startup Waiting Time
2 s max.
Electrical
Power Supply Voltage (Vs)
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current Consumption
Refer to
Safety Outputs (OSSD)
Two PNP or NPN transistor outputs (PNP or NPN
is selectable by DIP Switch.)
F3SG-
RE
P
: Two PNP transistor
outputs
F3SG-
RE
N
: Two NPN transistor
outputs
Load current of 300 mA max., Residual voltage of 2 V max. (except for voltage drop due to cable
extension), Capacitive load of 1
F max., Inductive load of 2.2 H max. *1
Leakage current of 1 mA max. (PNP), 2 mA max. (NPN) *2
*1. The load inductance is the maximum value when the safety output frequently repeats ON and OFF.
When you use the safety output at 4 Hz or less, the usable load inductance becomes larger.
*2. These values must be taken into consideration when connecting elements including a capacitive
load such as a capacitor.
Auxiliary Output
One PNP or NPN transistor output (PNP or NPN is
selectable by DIP Switch.)
Load current of 100 mA max., Residual voltage of
2 V max .
-
Output Operation
Mode
Safety
Output
Light-ON (Safety output is enabled when the receiver receives an emitting signal.)
Auxiliary
Output
Safety output (Inverted signal output:Enable)
(default) (Cofigurable by Configuration Tool)
-
Содержание F3SG-RA
Страница 1: ...F3SG R Series Safety Light Curtain User s Manual Cat No Z352 E1 08 http www ia omron com f3sg r...
Страница 16: ...xiv Introduction F3SG R User s Manual...
Страница 24: ...xxii Introduction F3SG R User s Manual...
Страница 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Страница 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Страница 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Страница 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...