PART 3: CX-Server Runtime
CHAPTER 4 – Import/Export Tool
OMRON
CX-Server Runtime_Page 42
Revision 2.0
Importing from FinsServer
Use the following procedure to import from FinsServer.
1, 2, 3…
1. Select
the
Import from TagDB
button from the toolbar. Provided FinsServer tagged
database utilities has been correctly installed, the FinsServer Import Option dialog is
displayed.
2.
Select the TagDB PLC name in the
Node in TagDB
field. Details of tags, device type and
network nodes are displayed below the list box.
•
+ The plus icon indicates that tagged data is assigned to the PLC listed in the
Node in
TagDB
field.
•
– The minus icon indicates that there is no tagged data assigned to the PLC listed in
the
Node in TagDB
field. It is not possible to import a node which has no tag data.
1. If required, enter a CX-Server project group name in the
Group Name
field ensuring that
the name does not exceed 64 characters. By default, the field is set to ‘FinsServer’.
2. Enter a PLC comment to be written to each imported tag data in the
Comment
field. By
default, the field is set to ‘Imported by FinsServer’.
3. Set
the
Import to same name PLC
field to ON to use the PLC in the current CX-Server
project. Deselect the
Import to same name PLC
field to select a specific PLC from the
PLC in Project
field. If necessary, PLC details can be edited via the
Edit Project
pushbutton.
Refer to Chapter 2 - Introduction to CX-Server Projects
for further
information.
4. Select the Import Tag pushbutton, an ‘Imported’ message is displayed once the operation
has concluded.
5. Select
the
Close
pushbutton. The success or failure of the import operation is displayed in
the Import/Export tool status dialog. Select the
OK
pushbutton to proceed.
Note:
The
Import Tag
pushbutton is disabled if the destination and source PLC types are
different. If there are other differences (apart from PLC type), the import can proceed
but no Export Log is generated.
The maximum size of a TagDB is as follows:
♦
Network: 20;
♦
Node: 100;
♦
Tag: 200 per Node.
The maximum size of a CX-Server project is as follows:
♦
PLC: 100;
♦
Points: 200 per PLC.
Export
PLC data can be exported to either text or FinsServer files, for example symbol definitions can be exported as a
FinsServer (‘.MDB’) file which can be read by Microsoft Excel (text files can also be imported into Microsoft
Excel).
Exporting Data to Text Files
Use the following procedure to export all of the points from a particular point group, which are linked to a
particular PLC (i.e. the point addresses refer to the PLC) to text file.
1, 2, 3…
1. Select
the
Export Text
button from the toolbar. The Export Text File dialog is displayed.
2. Select a PLC from the
Source PLC
field.
3. It is possible to extract only partial data by inserting a path for a particular point by
entering a pathname in
Source Point Group
field.
Содержание CX-Programmer 9
Страница 1: ...Cat No W446 E1 10 CX Programmer Ver 9 SYSMAC WS02 CXPC_ V9 OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC WS02 CXPC V9 CX Programmer Ver 9 Operation Manual Revised December 2009...
Страница 4: ......
Страница 6: ......
Страница 19: ...CX Programmer_Page xvi Unit Versions and Lot Numbers...
Страница 30: ......
Страница 31: ...PART 1 CX Programmer...
Страница 32: ......
Страница 100: ......
Страница 120: ......
Страница 198: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 118...
Страница 224: ...PART 1 CX Programmer Keyboard Shortcuts CX Programmer OMRON CX Programmer _Page 144...
Страница 240: ......
Страница 241: ...PART 2 CX Server PLC Tools...
Страница 242: ......
Страница 250: ......
Страница 256: ......
Страница 268: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 286: ......
Страница 338: ......
Страница 382: ......
Страница 414: ......
Страница 430: ......
Страница 436: ......
Страница 437: ...PART 3 CX Server Runtime...
Страница 438: ......
Страница 482: ......
Страница 488: ......
Страница 504: ......
Страница 530: ......
Страница 540: ......
Страница 541: ......
Страница 542: ......