PART 2: CX-Server PLC Tools
OMRON
CHAPTER 3 – IO Table Component
CX-Server PLC Tools_ Page 27
Creating an IO Table
Creation of an IO Table whilst connected to a PLC causes the Actual IO Table in the hardware to be written to the
Registered IO Table. An IO Table can also be edited offline and stored to file, this method is usually employed
when designing a PLC’s IO Table.
To create an IO Table, Select
Create
from the
Options
menu.
Slot Allocation
Use the following procedure to allocate a unit to a slot.
1, 2, 3…
1. Select an empty slot in the IO Table component.
2. Click the right-mouse button and select a unit. For Single and Multiple IO Units a
secondary selection is required from the right-mouse button menu. The type of PLC series
and individual rack configurations determine the units that can be installed and therefore
the content of the right-mouse button menu. The types of unit that can be selected are
described in following paragraphs.
Slots can also be allocated by transferring the rack information from the PLC. Refer to
IO Table Component
in this
chapter for information regarding transferring IO Table information from the PLC.
For CS/CJ/CP series PLCs, the IO fields for racks, slots and units information can be edited directly in the IO
Table tree.
Only those units in the Registered IO Table for CS/CJ/CP series PLCs, C200H (including C200HS/X/G/E) PLCs
and CV/CVM1-series PLCs can be edited.
Note:
Any slots allocated must be verified to ensure that the Real IO Table has been setup up
correctly.
Single and Multiple Units
Points with an IO Type of Input, Output or Input/Output can be applied to the IO Table component. Each point
contains a name and an address indicating its position in PLC memory. The information contained within a point
can be read or updated by the controlling system and its status and content stored in the system’s database. An
application accesses this point data by establishing a link between the application and the database. A point can
have the same address as another and any comment entered against this address applies to all points at that
location.
All PLC series support 8-point, 16-point, 32-point and 64-point Units. CV-series PLCs and CS/CJ/CP-series
PLCs also support 128-point and 256-point Units.
Refer to the Run Time manual
for an introduction to points.
Counters, Position Controller, Numerical Control and ASCII Units
Use the following procedure to apply unit settings to Counters, Position Controllers, Numerical Control and
ASCII units.
1, 2, 3…
1. Allocate a slot to be a Counter unit, Position Controller unit, Numerical Control unit or
ASCII unit. The Enter SIOU Details dialog is displayed.
2. Enter valid settings for the
Unit Number
field,
Address per Unit
field,
Input Words
field
and
Output Words
field. Valid settings exclude those settings that have already been used.
3. Select
the
OK
pushbutton to complete the operation or the
Cancel
pushbutton to abort the
operation.
Additionally for Counters, Numerical Control and ASCII units, for CV-series PLCs and CS/CJ/CP series PLCs,
the CIO and DM Address range need to be specified; refer to
Chapter 3 - Software Switches
for further
information.
Interrupt Units
Interrupt units are automatically assigned until the maximum number of units has been reached.
Sysmac-Bus Master Unit and Remote Terminals
If the
Sysmac-Bus Master
option is selected from the context menu, the hierarchy in the IO Table component can
be further expanded to expose the Remote Terminals and IO Terminals that form part of the SYSMAC-BUS
option. Use the following procedure to apply unit settings to Sysmac-Bus Master.
Содержание CX-Programmer 9
Страница 1: ...Cat No W446 E1 10 CX Programmer Ver 9 SYSMAC WS02 CXPC_ V9 OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC WS02 CXPC V9 CX Programmer Ver 9 Operation Manual Revised December 2009...
Страница 4: ......
Страница 6: ......
Страница 19: ...CX Programmer_Page xvi Unit Versions and Lot Numbers...
Страница 30: ......
Страница 31: ...PART 1 CX Programmer...
Страница 32: ......
Страница 100: ......
Страница 120: ......
Страница 198: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 118...
Страница 224: ...PART 1 CX Programmer Keyboard Shortcuts CX Programmer OMRON CX Programmer _Page 144...
Страница 240: ......
Страница 241: ...PART 2 CX Server PLC Tools...
Страница 242: ......
Страница 250: ......
Страница 256: ......
Страница 268: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 286: ......
Страница 338: ......
Страница 382: ......
Страница 414: ......
Страница 430: ......
Страница 436: ......
Страница 437: ...PART 3 CX Server Runtime...
Страница 438: ......
Страница 482: ......
Страница 488: ......
Страница 504: ......
Страница 530: ......
Страница 540: ......
Страница 541: ......
Страница 542: ......