PART 1: CX-Programmer
CX-Programmer_Page (v)
Previous version (version 8.3)
New version (version 9.0)
Replacements can be performed only in the
entire PLC or in the data in the current view.
"Programs" has been added to the replacement
range.
Also, the selected circuits can be set as the
replacement range.
The setting for the item to be replaced was very
detailed and included bit addresses, address,
values (constants/numbers), mnemonics,
symbols, and I/O comments.
Searched objects have been grouped into
addresses, symbol names, mnemonics, and
comments.
Version 8.3 Upgrade Information
Functionality Improved from Version 8.2 to 8.3
Compatible PLC Models
The functionality improvements are supported for CJ2H CPU Units with unit version
1.2 or later.
TIMER and COUNTER Added as Symbol Data Types
Previous version (version 8.2)
New version (version 8.3)
When defining timer numbers and counter
numbers as symbols, the following three different
symbols had to be registered in the symbols
table.
1.
Timer numbers and counter numbers
specified in instruction operands had to
be defined as NUMBER symbols.
2.
Timer and Counter Completion Flags
had to be defined as BOOL symbols.
3.
Timer and counter present values had
to be defined as CHANNEL symbols.
TIMER and COUNTER symbols are supported
so that all of the previous three types of symbols
can be managed as one data type. (TIMER and
COUNTER are supported only by CJ2H CPU
Units with unit version 1.0 or later.)
TIMER: Can be used for 1) the timer number, 2)
the Timer Completion Flag, and 3) the timer
present value.
COUNTER: Can be used for 1) the counter
number, 2) the Counter Completion Flag, and 3)
the counter present value.
Automatically assigning timer and counter
numbers in ladder programs was not possible.
Automatic address assignment and layout are
supported for TIMER and COUNTER symbols.
(TIMER and COUNTER are supported only by
CJ2H CPU Units with unit version 1.0 or later.)
Force-setting/resetting Bits in EM Area
Previous version (version 8.2)
New version (version 8.3)
Bits in the EM Area could be force-set/reset in
CJ2H CPU Units only for specific EM Area banks
for which automatic address assignment was
used.
With CJ2H CPU Units with unit version 1.2 or
later,
PLC • Memory Allocate • EM Memory
Settings
can be used to specify the EM Area
banks for which bits can be force-set/reset. (The
first bank is specified and force-setting/resetting
bits is possible in that bank and all banks
following it.) This is called the EM Area force-
setting/resetting function.
Searching for Symbol Names and Displaying Usage Locations from Cross-reference Pop-
ups
Previous version (version 8.2)
New version (version 8.3)
Searching from cross-reference pop-ups was
possible only for address specifications. (To
search for symbols, you had to click the
Browse
button and search for symbol names from the
Symbol Search Dialog Box.)
Symbol names can be specified directly in cross-
reference pop-ups to display a list of locations
that use the address of that symbol.
Содержание CX-Programmer 9
Страница 1: ...Cat No W446 E1 10 CX Programmer Ver 9 SYSMAC WS02 CXPC_ V9 OPERATION MANUAL...
Страница 2: ......
Страница 3: ...SYSMAC WS02 CXPC V9 CX Programmer Ver 9 Operation Manual Revised December 2009...
Страница 4: ......
Страница 6: ......
Страница 19: ...CX Programmer_Page xvi Unit Versions and Lot Numbers...
Страница 30: ......
Страница 31: ...PART 1 CX Programmer...
Страница 32: ......
Страница 100: ......
Страница 120: ......
Страница 198: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 118...
Страница 224: ...PART 1 CX Programmer Keyboard Shortcuts CX Programmer OMRON CX Programmer _Page 144...
Страница 240: ......
Страница 241: ...PART 2 CX Server PLC Tools...
Страница 242: ......
Страница 250: ......
Страница 256: ......
Страница 268: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Страница 286: ......
Страница 338: ......
Страница 382: ......
Страница 414: ......
Страница 430: ......
Страница 436: ......
Страница 437: ...PART 3 CX Server Runtime...
Страница 438: ......
Страница 482: ......
Страница 488: ......
Страница 504: ......
Страница 530: ......
Страница 540: ......
Страница 541: ......
Страница 542: ......