2-2
Connecting Online to the Relay PLC
2-2-2 Procedures
Item
Contents
Device Name
Relay Device (fixed)
Series
Device Type
CPU Unit model
CS1H CS1H-CPU67/66/65/64/63(-V1)
CS1G/CJ1G CS1G-CPU45/44/43/42(-V1)
CS1G-H CS1G-CPU45H/44H/43H/42H
CS1H-H CS1H-CPU67H/66H/65H/64H/63H
CS1D-H CS1D-CPU67H/65H
CS Series
CS1D-S CS1D-CPU67S/65S/44S/42S
CS1G/CJ1G CJ1G-CPU45/44
CJ1M CJ1M-CPU23/22/21/13/12/11
CJ1G-H CJ1G-
CPU45H/44H/43H/42H
CJ Series
CJ1H-H CJ1H-CPU67H/66H/65H
CP1H-XA CP1H-XA
@@@@
-
@
CP-Series
CP1H-X CP1H-X
@@@@
-
@
NSJ Series
NSJ
G5D (Used for the NSJ5-TQ0
@
-G5D,
NSJ5-SQ0
@
-G5D, NSJ8-TV0
@
-G5D,
NSJ10-TV0
@
-G5D, and
NSJ12-TS0
@
-G5D.)
Device Type
- CompoWay/F
Device
Select CompoWay/F Device to connect
the computer running CX-Integrator
directly as a CompoWay/F slave using
serial communications.
Select one of the following network types.
Network type
Contents
Toolbus
Select to connect the computer with a direct serial
connection using the Toolbus protocol.
Note:
The Toolbus (peripheral) protocol is faster
than the SYSMAC WAY protocol. Serial
connections are generally made using this
network type.
SYSMAC WAY
Select to connect the computer with a direct serial
connection using the SYSMAC WAY protocol.
Note:
The SYSMAC WAY protocol enables 1:N
connections, which are not possible for the
Toolbus protocol.
Ethernet
Select to connect the computer directly to an Ethernet
network using the Ethernet UDP/IP protocol.
Ethernet (FINS/TCP)
Select to connect the computer directly to an Ethernet
network using the Ethernet TCP/IP protocol.
FinsGateway
Select to use FinsGateway for communications.
(Selected when using FinsGateway for all
communications.)
Controller Link
Select to connect the computer directly to a Controller
Link network through a Controller Link Support Board.
SYSMAC LINK
Select to connect the computer directly to a SYSMAC
LINK network through a SYSMAC LINK Support
Board.
CompoWay/F
Select to connect the computer with a direct serial
connection to a CompoWay/F slave.
Network Type
USB
Select to connect the computer directly to an
NSJ-series NSJ Controller using a USB cable.
Click the
Settings
Button to display the Network Settings Dialog Box for each type of
network. Details are described here for Toolbus, SYSMAC WAY, and Ethernet. Refer
to the
CX-Programmer
Operation Manual
for other methods.
2-14
Содержание CX-INTEGRATOR - V1.1
Страница 1: ...OPERATION MANUAL CX Integrator Ver 1 1 SYSMAC CXONE AL C E Cat No W445 E1 02...
Страница 2: ...CXONE AL C E CX Integrator Ver 1 1 Operation Manual Revised November 2005...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 13: ...xiv...
Страница 120: ...Communications Section 3 Routing Tables This section describes how to set the routing tables 3...
Страница 200: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet 5...
Страница 292: ...Communications Section 8 NT Links This section explains the settings and operations specific to the NT Link system 8...
Страница 328: ...Appendices A...
Страница 336: ......