7-2
CompoWay/F Slaves Connected to a PLC
7-2-1
Communications with CompoWay/F Slaves through a PLC
5. Right-click the Serial Communications Unit in the Online Connection Information
Window and select
Transfer [Network to PC]
.
6. The following confirmation dialog box will be displayed.
Click the
Yes
Button.
7. The Compoway/F Finding node settings Dialog Box will be displayed.
If the CompoWay/F Slave node’s
node address is unknown:
Select the
All (0-99)
Option.
If the CompoWay/F Slave node’s
node address is known:
Select the
Selection
Option and set the minimum and
maximum addresses for the CompoWay/F Slave node
address range.
Note
If you already know the range of node addresses set for the CompoWay/F Slaves,
select the
Selection
Option, specify the node address search range (finding node
range), and transfer the node parameters.
The search will take about 20 seconds for each node that is not actually connected, so
it will take about 35 minutes for the transfer to be completed if the
All(0-99)
Option is
selected. For the same reason, the transfer will take longer if the
Selection
Option is
selected and the maximum node address is higher than the node address of the nodes
actually connected.
7-5
Содержание CX-INTEGRATOR - V1.1
Страница 1: ...OPERATION MANUAL CX Integrator Ver 1 1 SYSMAC CXONE AL C E Cat No W445 E1 02...
Страница 2: ...CXONE AL C E CX Integrator Ver 1 1 Operation Manual Revised November 2005...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 13: ...xiv...
Страница 120: ...Communications Section 3 Routing Tables This section describes how to set the routing tables 3...
Страница 200: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet 5...
Страница 292: ...Communications Section 8 NT Links This section explains the settings and operations specific to the NT Link system 8...
Страница 328: ...Appendices A...
Страница 336: ......