4-4
Automatically Set Data Links
4-4-5
Monitoring Data Link Status
The following information is displayed in the
Network Properties
Area.
Data link start node
Polling node number
Network cycle time
Current and maximum data link refresh
times
The following information is displayed in the
Operational Status
Area.
CPU Unit errors
Data link status
CPU Unit’s operating mode
Communications status
Checking Automatically Set Data Link Tables
The Data Link Component Window is designed for manually setting data links. If data
link status is read from the Data Link Component while automatically set data links are
running, the data links may not be displayed properly. Furthermore, if the data link
tables that were read are then downloaded to a PLC, the data link tables that were
originally in the PLC will be overwritten. To prevent these problems, use the following
method to check automatically set data link tables.
1. Place the CX-Integrator online with the network PLC from which automatically set
data link tables are to be read.
2. Select
Tools - Start Data Link
from the menu bar to open the Data Link
Component.
3. Select
Online - Datalink Operation/Status
from the Data Link Component menu
bar.
4. The Datalink Status Dialog Box will be displayed.
Check the data link start node.
Confirm the data
link start node here.
4-51
Содержание CX-INTEGRATOR - V1.1
Страница 1: ...OPERATION MANUAL CX Integrator Ver 1 1 SYSMAC CXONE AL C E Cat No W445 E1 02...
Страница 2: ...CXONE AL C E CX Integrator Ver 1 1 Operation Manual Revised November 2005...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 13: ...xiv...
Страница 120: ...Communications Section 3 Routing Tables This section describes how to set the routing tables 3...
Страница 200: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet 5...
Страница 292: ...Communications Section 8 NT Links This section explains the settings and operations specific to the NT Link system 8...
Страница 328: ...Appendices A...
Страница 336: ......