5-2 Ping
Test
5-2-1 Overview
5-2 Ping
Test
5-2-1 Overview
The connection status of a target PLC can be checked by executing a ping test from a
PLC node connected on an Ethernet network. In the example shown here, PLC1 is
serially connected and a ping test is executed to check whether PLC3 is connected to
the Ethernet network.
Computer (CX-Integrator)
CJ-series CJ-series PLC1
IP address: 192.168.200.104
Network address: 10
Node address: 104
CJ-series PLC2
IP address: 192.168.200.105
Network address: 10
Node address: 105
CS-series PLC3
IP address: 192.168.200.185
Network address: 1
Node address: 185
Example:
HUB
Ethernet
PING Test 192.168.200.185
PING
Toolbus
5-2-2 Procedure
1. After PLC1 is serially connected by an automatic online connection, right-click the
Ethernet Unit and select
Connect
.
2. After connecting to Ethernet, right-click the Ethernet Unit in the Online Connection
Information Window and select
Ethernet tool -
Ping test
.
5-4
Содержание CX-INTEGRATOR - V1.1
Страница 1: ...OPERATION MANUAL CX Integrator Ver 1 1 SYSMAC CXONE AL C E Cat No W445 E1 02...
Страница 2: ...CXONE AL C E CX Integrator Ver 1 1 Operation Manual Revised November 2005...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 13: ...xiv...
Страница 120: ...Communications Section 3 Routing Tables This section describes how to set the routing tables 3...
Страница 200: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet 5...
Страница 292: ...Communications Section 8 NT Links This section explains the settings and operations specific to the NT Link system 8...
Страница 328: ...Appendices A...
Страница 336: ......