Appendices
A-10
EtherCAT Communication Unit USER’S MANUAL (3G3AX-MX2-ECT)
3000
hex
1D
hex
001C
hex
Fault Monitor 2
Cause
d082
RO
Refer to
Inverter fault factor list
on
page A-12.
Possible
(TxPDO)
3000
hex
1E
hex
001D
hex
Fault Monitor 2
Inverter Status
Refer to
Inverter fault factor list
on
page A-12.
Possible
(TxPDO)
4000
hex
1F
hex
001E
hex
Fault Monitor 2
Frequency
0 to 100000
0.01 [Hz]
Possible
(TxPDO)
3000
hex
21
hex
0020 hex
Fault Monitor 2
Current
Output current value at the time of
tripping
0.01 [A]
Possible
(TxPDO)
3000
hex
22
hex
0021 hex
Fault Monitor 2 Voltage
DC input voltage at the time of
tripping
0.1 [V]
Possible
(TxPDO)
4000
hex
23
hex
0022 hex
Fault Monitor 2
RUN Time
Total RUN time at the time of
tripping
1 [h]
Possible
(TxPDO)
4000
hex
25
hex
0024 hex
Fault Monitor 2
ON Time
Power ON time at the time of
tripping
1 [h]
Possible
(TxPDO)
3000
hex
27
hex
0026 hex
Fault Monitor 3
Cause
d083
RO
Refer to
Inverter fault factor list
on
page A-12.
Possible
(TxPDO)
3000
hex
28
hex
0027 hex
Fault Monitor 3
Inverter Status
Refer to
Inverter fault factor list
on
page A-12.
Possible
(TxPDO)
4000
hex
29
hex
0028 hex
Fault Monitor 3
Frequency
0 to 100000
0.01 [Hz]
Possible
(TxPDO)
3000
hex
2B
hex
002A
hex
Fault Monitor 3
Current
Output current value at the time of
tripping
0.01 [A]
Possible
(TxPDO)
3000
hex
2C
hex
002B
hex
Fault Monitor 3 Voltage
DC input voltage at the time of
tripping
0.1 [V]
Possible
(TxPDO)
4000
hex
2D
hex
002C
hex
Fault Monitor 3
RUN Time
Total RUN time at the time of
tripping
1 [h]
Possible
(TxPDO)
4000
hex
2F
hex
002E
hex
Fault Monitor 3
ON Time
Power ON time at the time of
tripping
1 [h]
Possible
(TxPDO)
3000
hex
31
hex
0030 hex
Fault Monitor 4
Cause
d084
RO
Refer to
Inverter fault factor list
on
page A-12.
Possible
(TxPDO)
3000
hex
32
hex
0031 hex
Fault Monitor 4
Inverter Status
Refer to
Inverter fault factor list
on
page A-12.
Possible
(TxPDO)
4000
hex
33
hex
0032 hex
Fault Monitor 4
Frequency
0 to 100000
0.01 [Hz]
Possible
(TxPDO)
3000
hex
35
hex
0034 hex
Fault Monitor 4
Current
Output current value at the time of
tripping
0.01 [A]
Possible
(TxPDO)
3000
hex
36
hex
0035 hex
Fault Monitor 4 Voltage
DC input voltage at the time of
tripping
0.1 [V]
Possible
(TxPDO)
4000
hex
37
hex
0036 hex
Fault Monitor 4
RUN Time
Total RUN time at the time of
tripping
1 [h]
Possible
(TxPDO)
4000
hex
39
hex
0038 hex
Fault Monitor 4
ON Time
Power ON time at the time of
tripping
1 [h]
Possible
(TxPDO)
3000
hex
3B
hex
003A
hex
Fault Monitor 5
Cause
d085
RO
Refer to
Inverter fault factor list
on
page A-12.
Possible
(TxPDO)
3000
hex
3C
hex
003B
hex
Fault Monitor 5
Inverter Status
Refer to
Inverter fault factor list
on
page A-12.
Possible
(TxPDO)
4000
hex
3D
hex
003C
hex
Fault Monitor 5
Frequency
0 to 100000
0.01 [Hz]
Possible
(TxPDO)
3000
hex
3F
hex
003E
hex
Fault Monitor 5
Current
Output current value at the time of
tripping
0.01 [A]
Possible
(TxPDO)
3000
hex
40
hex
003F hex
Fault Monitor 5 Voltage
DC input voltage at the time of
tripping
0.1 [V]
Possible
(TxPDO)
4000
hex
41
hex
0040 hex
Fault Monitor 5
RUN Time
Total RUN time at the time of
tripping
1 [h]
Possible
(TxPDO)
4000
hex
43
hex
0042 hex
Fault Monitor 5
ON Time
Power ON time at the time of
tripping
1 [h]
Possible
(TxPDO)
Index
Sub-
index
Register
No.
Function name
Parameter
No.
R/W
Monitor and setting items
Data
resolution
PDO
map
Содержание 3G3AX-MX2-ECT
Страница 23: ...20 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT CONTENTS ...
Страница 31: ...1 EtherCAT Network 1 8 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT ...
Страница 85: ...4 Inverter Control 4 18 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT ...
Страница 111: ...5 CiA402 Drive Profile 5 26 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT ...
Страница 162: ...Index 1 EtherCAT Communication Unit USER S MANUAL 3G3AX MX2 ECT I Index ...
Страница 164: ......