1-6-46
(4) Detaching and refitting the ISU (reference)
Follow the procedure below to check or replace the ISU.
Caution
After replacing the ISU, perform (6-2) Adjusting the position of the ISU (see page 1-6-50).
Fitting requires the following tools
Two positions pin
s
Procedure
1. Remove two screws of hinge retainer at the
rear side of the left hinge and then remove
the retainer from DP.
2. Remove the upper right cover and contact
glass (see page 1-6-34).
3. Remove four screws and then remove the
ISU cover.
Figure 1-6-90
4. Remove three flexible flat cables.
5. Remove the four screws and then ISU from
the machine.
Figure 1-6-91
ISU cover
ISU
Flexible flat cables
Service Manual Y104350-7