1-5-36
C5600
Drum surface potential problem 1
• Maximizing the grid output cannot set
the potential.
Deteriorated main
charger.
Check the main charger wire and replace it if
necessary (see page 1-6-33).
Grid or main
charger shield is
dirty.
Clean the grid or main charger shield if nec-
essary.
Defective drum
surface potential
sensor.
Replace the drum surface potential sensor.
Defective high volt-
age PWB.
Replace the high voltage PWB and check
for correct operation.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation.
C5610
Drum surface potential problem 2
• Minimizing the grid output cannot set
the potential.
Defective drum
surface potential
sensor.
Replace the drum surface potential sensor.
Defective high volt-
age PWB.
Replace the high voltage PWB and check
for correct operation.
C6000
Fuser heater lamp break
• The fuser temperature does not
increase for 40 s after the fuser heat-
ers have been turned on for warming
up.
• The fuser temperature remains below
50
°
C/122
°
F for 10 s continuously
after the fuser heaters have been
turned on during stabilization.
Installation defec-
tiveness on fuser
thermistor M and
S.
Check the mounting state of the fuser ther-
mistor M and S. If any problem is found,
repair it.
Defective fuser
thermostat.
Replace the fuser thermostat (see page 1-6-
75).
Installation defec-
tiveness on fuser
heater L, M or S.
Check the mounting state of the fuser ther-
mistor L, M and S. If any problem is found,
repair it.
Broken fuser
heater L, M and S
wire.
Check for continuity. If none, replace the
fuser heater L, M and S (see page 1-6-76).
Defective engine
PWB.
Replace the engine PWB.
Defective AC
power source
PWB.
Replace the AC power source PWB.
C6020
Fuser thermistor high-temperature
detection error
• The fuser temperature exceeds 235
°
C/455
°
F for 10 s.
Installation defec-
tiveness on fuser
thermistor M and
S.
Check the mounting state of the fuser ther-
mistor M and S. If any problem is found,
repair it.
Defective fuser
thermistor M and
S.
Replace the fuser thermistor M and S (see
page 1-6-75).
C6030
Fuser thermistor break error
• The fuser temperature remains at 0
°
C/32
°
F for 30 s continuously when
the fuser heater is on.
Defective engine
PWB.
Replace the engine PWB.
Defective AC
power source
PWB.
Replace the AC power source PWB.
Installation defec-
tiveness on fuser
thermistor M and
S.
Check the mounting state of the fuser ther-
mistor M and S. If any problem is found,
repair it.
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Service Manual Y104350-7
Содержание d-Copia 600
Страница 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Страница 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Страница 10: ......
Страница 34: ......
Страница 83: ...This page is intentionally left blank...
Страница 314: ...This page is intentionally left blank...
Страница 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...