1-4-62
U342
Setting the ejection restriction
Description
Sets or cancels the restriction on the number of sheets to be ejected continuously when the internal eject tray
is selected as the eject location.
Purpose
According to user request, sets or cancels restriction on the number of sheets.
Method
1. Press the start key. The screen for selecting an item is displayed.
2. Select ON or OFF.
Initial setting: ON
3. Press the start key. The setting is set.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
U343
Switching between duplex/simplex copy mode
Description
Switches the initial setting between duplex and simplex copy.
Purpose
To be set according to frequency of use: set to the more frequently used mode.
Setting
1. Press the start key. The screen for selecting an item is displayed.
2. Select ON or OFF. The selected item is displayed in reverse.
Initial setting: OFF
3. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
U344
Setting the low-power mode
Description
Changes the control for low-power mode.
Purpose
According to user request, selects which has priority, the recovery time from low-power or energy saver.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select control mode. The selected item is displayed in reverse.
Initial setting: ENERGY STAR (120 V specifications)/GEEA (220-240 V specifications)
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
Press the stop/clear key at the screen for selecting an item.
The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
ON
Sets restriction on the number of sheets
OFF
Cancels restriction on the number of sheets
Display
Description
ON
Duplex copy
OFF
Simplex copy
Display
Description
ENERGY STAR
The fuser control temperature is lowered by 20
°
C/68
°
F and forced
stabilization is performed 30 seconds after exiting preheat.
GEEA
The fuser control temperature is lowered by 15
°
C/59
°
F and forced
stabilization is performed 30 seconds after exiting preheat.
Service Manual Y104350-7
Содержание d-Copia 600
Страница 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Страница 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Страница 10: ......
Страница 34: ......
Страница 83: ...This page is intentionally left blank...
Страница 314: ...This page is intentionally left blank...
Страница 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...