1-5-70
(6)
The CIS does not
turn on.
Poor contact in the CIS con-
nector terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective DP inverter PWB. Run maintenance item U061 and check if the CIS turns on when
the connector on the DP inverter PWB goes low. If not, replace the
DP inverter PWB.
Defective DP main PWB.
Run maintenance item U061 and check if the CIS turns on when
YC12-2 on the DP main PWB goes low. If not, replace the DP
main PWB.
(7)
The CIS does not
turn off.
Defective DP inverter PWB. Check if the CIS turns off when the connector on the DP inverter
PWB goes high. If not, replace the DP inverter PWB.
Defective DP main PWB.
If YC12-2 on the DP main PWB is always low, replace the DP
main PWB.
(8)
A message indication
cover open is dis-
played when the DP
is closed correctly.
Poor contact in DP safety
switch 1 connector termi-
nals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective DP safety switch
1.
Check for continuity across the contacts of the switch. If none
when the switch is on, replace DP safety switch 1.
Poor contact in DP safety
switch 2 connector termi-
nals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective DP safety switch
2.
Check for continuity across the contacts of the switch. If none
when the switch is on, replace DP safety switch 2.
(9)
The size of original is
not displayed cor-
rectly.
Poor contact in the original
length size switch connec-
tor terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective original length
size switch.
Run maintenance item U244 and turn the original length size
switch on and off manually. Replace the original length size switch
if indication of the corresponding switch on the touch panel is not
displayed in reverse.
Poor contact in the original
width size switch connector
terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective original width size
switch.
Check if the level of YC8-5 on the DP main PWB change alter-
nately when the original width guides are moved. If not, replace
the original width size switch.
Problem
Causes
Check procedures/corrective measures
Service Manual Y104350-7
Содержание d-Copia 600
Страница 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Страница 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Страница 10: ......
Страница 34: ......
Страница 83: ...This page is intentionally left blank...
Страница 314: ...This page is intentionally left blank...
Страница 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...