1-5-35
C4110
BD initialization (B) problem
• When power is turned on, only laser B
is output and ASIC of main PWB
detects a BD error for 2000 ms.
Defective laser
scanner unit.
Replace the laser scanner unit (see page 1-
6-42).
Defective main
PWB.
Replace the main PWB and check for cor-
rect operation.
Poor contact in
connector termi-
nals.
Check the connection of connector YC8 on
the main PWB and the continuity across the
connector terminals. Repair or replace if
necessary.
C4120
BD initialization (C) problem
• When power is turned on, only laser C
is output and ASIC of main PWB
detects a BD error for 2000 ms.
Defective laser
scanner unit.
Replace the laser scanner unit (see page 1-
6-42).
Defective main
PWB.
Replace the main PWB and check for cor-
rect operation.
Poor contact in
connector termi-
nals.
Check the connection of connector YC8 on
the main PWB and the continuity across the
connector terminals. Repair or replace if
necessary.
C4200
BD steady-state problem
• ASIC of the main PWB detects a BD
error A for 4000 ms after the polygon
motor rotation has been stabilized.
Defective laser
diode.
Replace the laser scanner unit (see page 1-
6-42).
Defective polygon
motor.
Replace the laser scanner unit (see page 1-
6-42).
Defective main
PWB.
Replace the main PWB and check for cor-
rect operation.
Poor contact in
connector termi-
nals.
Check the connection of connector YC8 on
the main PWB and the continuity across the
connector terminals. Repair or replace if
necessary.
C5100
Main high-voltage error
• While the main high-voltage output
remote signal is on, an alarm signal is
detected continuously for 400 ms.
Defective high volt-
age PWB.
Replace the high voltage PWB and check
for correct operation.
Leak of main high-
voltage.
Check the main charger unit and replace if
necessary (see page 1-6-31).
C5500
Drum surface potential sensor prob-
lem 1
• The sensor output is 0.5 V or less
when MC REM signal is turned on.
Poor contact in the
drum surface
potential sensor
connector termi-
nals.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
repair or replace the cable.
Defective drum
surface potential
sensor.
Replace the drum surface potential sensor.
Defective high volt-
age PWB.
Replace the high voltage PWB and check
for correct operation.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation.
C5510
Drum surface potential sensor prob-
lem 2
• The sensor output is 4.5 V or more
when the MC REM signal is turned on.
Defective drum
surface potential
sensor.
Replace the drum surface potential sensor.
Defective high volt-
age PWB.
Replace the high voltage PWB and check
for correct operation.
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Y104350-7 Sevice Manual
Содержание d-Copia 600
Страница 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Страница 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Страница 10: ......
Страница 34: ......
Страница 83: ...This page is intentionally left blank...
Страница 314: ...This page is intentionally left blank...
Страница 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...