1-6-81
6. Remove seven springs from the separation
claws and then pull out the separation claws
shaft from the eject guide.
7. Replace the separation claws and attach the
claws to the eject guide.
8. Refit the eject guide.
Figure 1-6-160
(10) Detaching and refitting the fuser eject upper roller
Follow the procedure below to replace the fuser eject upper roller.
Procedure
1. Remove the eject guide from the eject sec-
tion (see page 1-6-80).
2. Remove the fuser eject upper roller from the
eject section.
3. Remove the two bearings from the fuser
eject upper roller.
4. Replace the fuser eject upper roller and
attach the roller to the eject section.
5. Refit the eject guide.
Figure 1-6-160-1
Eject guide
Separation
claws shaft
Spring
Springs
Separation
claw
Eject section
Fuser eject upper roller
Bearing
Bearing
Y104350-7 Sevice Manual