![Olivetti d-Copia 600 Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/olivetti/d-copia-600/d-copia-600_service-manual_3902246103.webp)
1-4-31
U101
Setting the other high voltages
Description
Sets the developing bias control voltage, the transfer control voltage, and the separation control voltage or
checks the output of these voltages.
Purpose
To check or change the developing bias, the transfer voltage, and the separation voltage.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select the item to be set.
2. Change the setting using the * or # keys.
3. Press the start key. The value is set.
PTC section operation check
1. Select PTC TEST at the screen for selecting an item.
2. Press the start key.
Drive motor, transfer motor and developing motor are turned on, and then cleaning lamp and PTC unit is
turned on.
Interrupt copy mode
While this maintenance item is being executed, copying from an original is available in the interrupt copying
mode.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for maintenance item No. is dis-
played.
Maintenance
item No.
Description
Display
Description
Setting
range
Default
setting
DEV BIAS SET
Developing bias control voltage
0 to 255
117
TC SET
Transfer control voltage
0 to 255
185 (80 cpm)
135 (60 cpm)
TC REV SET
Reverse transfer control voltage
0 to 255
200
VPP SET
VPP setting value
60 to 196
145
PTC TEST
PTC section operation check
-
-
Y104350-7 Sevice Manual
Содержание d-Copia 600
Страница 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Страница 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Страница 10: ......
Страница 34: ......
Страница 83: ...This page is intentionally left blank...
Страница 314: ...This page is intentionally left blank...
Страница 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...