1-4-59
U326
Setting the black line cleaning indication
Description
Sets whether to display the cleaning guidance when detecting the black line.
Purpose
Displays the cleaning guidance in order to make the call for service with the black line decrease by the rubbish
on the contact glass when scanning from the DP.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Initial setting: ON
Setting count value is displayed only if the setting is ON.
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Setting the count value
1. Enter a three-digit value using the # or * key, or numeric keys. and then press the start key. The value is
set.
When setting is 0, the black line cleaning indication is displayed only if the black line is detected.
2. To clear the count, press the reset key and then press the start key. The count is cleared and the screen
for selecting a maintenance item is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U327
Setting the drawer heater ON/OFF
Description
Sets ON/OFF of the drawer heater and optional side feeder dehumidifier.
Purpose
To change the setting when dew condensation on the drum is heavy.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Initial setting: Drawer heater OFF, side feeder dehumidifier OFF
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
ON
Displays the cleaning guidance
OFF
Not to display the cleaning guidance
COUNT
Setting counts of the cleaning guidance indication
Display
Description
CASSETTE ON
Drawer heater ON
CASSETTE OFF
Drawer heater OFF
SIDE FEEDER ON
Side feeder dehumidifier heater ON
SIDE FEEDER OFF
Side feeder dehumidifier heater OFF
Y104350-7 Sevice Manual
Содержание d-Copia 600
Страница 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Страница 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Страница 10: ......
Страница 34: ......
Страница 83: ...This page is intentionally left blank...
Страница 314: ...This page is intentionally left blank...
Страница 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...