![Olivetti d-Copia 600 Скачать руководство пользователя страница 125](http://html1.mh-extra.com/html/olivetti/d-copia-600/d-copia-600_service-manual_3902246125.webp)
1-4-53
U248
Setting the punch limit
1. Select PUNCH PRESET at the screen for selecting an item.
2. Change the value using the * or # keys.
The punch limit can be set to any value in increments of 1000.
3. Press the start key. The value is set.
4. To return to the screen for selecting an item, press the stop/clear key.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
U250
Setting the maintenance cycle
Description
Displays and changes the maintenance cycle.
Purpose
To check and change the maintenance cycle.
Method
Press the start key. The currently set maintenance cycle is displayed.
Setting
1. Select the item to be set. The selected item is displayed in reverse.
2. Change the setting value (0 to 9999999) using the numeric keys.
3. Press the start key. The value is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
U251
Checking/clearing the maintenance count
Description
Displays, clears and changes the maintenance count.
Purpose
To check the maintenance count. Also to clear the count during maintenance service.
Method
Press the start key. The maintenance count is displayed.
Clearing
1. Select the item to be cleared.
2. Press the reset key.
3. Press the start key. The count is cleared, and the screen for selecting a maintenance item No. is dis-
played.
Setting
1. Enter a seven-digit count using the numeric keys.
2. Press the start key. The count is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the count, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Description
Setting range
Default setting
Punch limit (max. number of punches)
0 to 999000
100000
Y104350-7 Sevice Manual
Содержание d-Copia 600
Страница 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Страница 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Страница 10: ......
Страница 34: ......
Страница 83: ...This page is intentionally left blank...
Страница 314: ...This page is intentionally left blank...
Страница 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...