1-5-64
(37)
The feedshift fan
motor does not oper-
ate.
Broken feedshift fan motor
coil.
Check for continuity across the coil. If none, replace the feedshift
fan motor.
Poor contact in feedshift fan
motor connector terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective feedshift fan
motor.
Run maintenance item U037 and check if the feedshift fan motor
operates when YC6-4 on the engine PWB goes low. If not, replace
the feedshift fan motor.
Defective engine PWB.
Run maintenance item U037 and check if YC6-4 on the engine
PWB goes low. If not, replace the engine PWB.
(38)
The duplex fan motor
does not operate.
Broken duplex fan motor
coil.
Check for continuity across the coil. If none, replace the duplex
fan motor.
Poor contact in duplex fan
motor connector terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective duplex fan motor.
Run maintenance item U037 and check if the duplex fan motor
operates when YC13-7 on the engine PWB goes low. If not,
replace the duplex fan motor.
Defective engine PWB.
Run maintenance item U037 and check if YC13-7 on the engine
PWB goes low. If not, replace the engine PWB.
(39)
The shield box fan
motor does not oper-
ate.
Broken shield box fan motor
coil.
Check for continuity across the coil. If none, replace the shield box
fan motor.
Poor contact in shield box
fan motor connector termi-
nals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
(40)
The MP solenoid
does not operate.
Broken MP solenoid coil.
Check for continuity across the coil. If none, replace the MP sole-
noid.
Poor contact in the MP
solenoid connector termi-
nals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective engine PWB.
Run maintenance item U033 and check if YC3-A8 and YC3-A9 on
the engine PWB go low. If not, replace the engine PWB.
Defective deck PWB.
Run maintenance item U033 and check if YC5-A2 and YC5-A3 on
the deck PWB go low. If not, replace the deck PWB.
(41)
The feedshift sole-
noid does not oper-
ate.
Broken feedshift solenoid
coil.
Check for continuity across the coil. If none, replace the feedshift
solenoid.
Poor contact in the feedshift
solenoid connector termi-
nals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective engine PWB.
Run maintenance item U033 and check if YC6-14 and YC6-16 on
the engine PWB go low. If not, replace the engine PWB.
(42)
The fuser web sole-
noid does not oper-
ate.
Broken fuser web solenoid
coil.
Check for continuity across the coil. If none, replace the fuser web
solenoid.
Poor contact in the fuser
web solenoid connector ter-
minals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Defective engine PWB.
Run maintenance item U033 and check if YC12-2 on the engine
PWB goes low. If not, replace the engine PWB.
Problem
Causes
Check procedures/corrective measures
Service Manual Y104350-7
Содержание d-Copia 600
Страница 1: ...d Copia 600 d Copia 800 Color Printer SERVICE MANUAL Code Y104350 7...
Страница 4: ...This page is intentionally left blank iv Service Manual Y104350 7...
Страница 10: ......
Страница 34: ......
Страница 83: ...This page is intentionally left blank...
Страница 314: ...This page is intentionally left blank...
Страница 454: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 02 2006 1ST EDITION 454 Y104350 7...