Page: 56
Service Guide OF1000
Chapter 2 Principles of Operation
2.5.08 Fusing
After transfer, the toner image is fused to the paper by heat and pressure. The paper passes
between the fusing roller and the pressure roller. The fusing roller has a teflon coating and
contains a 400 watt halogen lamp. A thermistor (which contacts the fusing roller) maintains the
fusing roller temperature at approximately 150 degrees Celsius. A thermostat cuts off the voltage
supply to the lamp if there is an abnormal temperature rise.
The pressure roller provides 2.5 Kg of pressure. This is generated by the pressure springs at each
side of the roller.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
Содержание OF1000
Страница 146: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 185: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 208: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 260: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 276: ...Page 182 Service Guide OF1000 Chapter 4 Failure Repair Analysis Sample Analysis of Protocol Dump Data...