Page: 173
Service Guide OF1000
Chapter 4 Failure & Repair Analysis
4.6.04 Tone Test
The Tone Test allows service technicians to test the frequencies used in handshaking.
Refer to
RAP 11
if the Tone Test should fail.
Procedure
1. Press
SELECT FUNCTION.
2. Press
COPY
twice.
3. Press
LEFT ARROW
twice.
4. Press the
"4"
Key on the ten-key pad.
5. Press
LEFT ARROW.
NOTE:
The CML Relay will energize connecting the Okifax 1000 to the phone line. Each frequency will be
sent from the LINE terminal for about five seconds. After the 1100 hz tone is sent, the CML Relay
will de-energize automatically.
6. Press
STOP
four times to exit the test.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)