Page: 43
Service Guide OF1000
Chapter 2 Principles of Operation
2.4.05 Fuser Unit
The fuser unit is controlled by a thermistor, the printer interface gate array, an LSI and the CPU to
keep the heat roller surface temperature within a predetermined range (about 150 degrees
Celsius). A thermal fuse within the fuser unit prevents abnormal temperature rises in case the
thermistor fails.
NOTE:
The CPU checks for an open circuit in the thermistor at power -on, setting a fuser alarm if this
error is detected.
The CPU also sets a fuser alarm if the proper temperature is not attained within a specified period
of time after power-on.
Upon detecting a fuser alarm, the CPU will halt (after printing the current page).
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
Содержание OF1000
Страница 146: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 185: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 208: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 260: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 276: ...Page 182 Service Guide OF1000 Chapter 4 Failure Repair Analysis Sample Analysis of Protocol Dump Data...