23
Document Top Feed
Adjusts the Start of Scan
Position of the ADF. The
selectable range is from -7 mm
to +10 mm in 1 mm increments.
0 mm
24
Document End Feed
Adjusts the End of Scan
Position of the ADF. The
selectable range is from -10 mm
to +10 mm (in 1 mm increments).
0 mm
25
Sensor Calibration
Select ON to enable calibration
of the scanner sensor (CIS).
This setting returns to OFF
once the scanner calibration
procedure has been executed.
OFF
26
Phone Dial
Switches the alternate FAX
telephone number to a regular
phone number for voice
communication.
OFF
27
Service Bit
ON: Technician's features are
available. OFF: Technician's
features are not available.
OFF
28
Video Parameter
Selects the non-photo mode
parameter (P1) and the
photomode parameter (P2) in the
form P1*P2.
1*1
29
MDY / DMY
Switches Operator Panel display
and report printing date format
between: MDY: Month/Day/Year
DMY: Day/Month/Year
DMY
30
CCITT ECM
Enables the use of the CCITT
Error Correction Mode.
ON
31
Receive in Memory
Enables the Memory RX Function
under the following conditions:
NO PAPER COVER OPEN PAPER JAM
ON
32
Page Retransmission
Enables page retransmission
from memory if a communications
error exists in non-ECM mode.
ON
33
Local Date and Time
Print
Enables the printing of the
Date/Time at the top of the
first received page.
OFF
34
XTTO Value
Selects the time duration (in
seconds) that the Okifax 1000
will wait for a remote
station's answer.
000
35
Receive in Memory
when Low Toner
Condition Exists
Enables the Memory RX Function
when a low toner condition
exists.
ON
36
RX Error Message
Print
Enables or disables the
printing of the message
RECEIVE STOPPED when reception
is interrupted.
ON
Содержание OF1000
Страница 146: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 185: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 208: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 260: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Страница 276: ...Page 182 Service Guide OF1000 Chapter 4 Failure Repair Analysis Sample Analysis of Protocol Dump Data...