Service Guide OF1000
Chapter 4 Failure & Repair Analysis
4.6.03 LED Test
The LED Test verifies the operation of the LEDs on the Operator Panel.
Refer to RAP 10()
if the
LED Test should fail.
Procedure
1. Press
SELECT FUNCTION.
2. Press
COPY
twice.
3. Press
LEFT ARROW
twice.
4. Press the
"3"
Key on the ten-key pad.
5. Press
LEFT ARROW.
The following message will be displayed.
3: LED TEST
BLINKING
Each LED will be turned ON sequentially for approximately one second in the following order.
- ALARM
- DARK
- NORMAL
- LIGHT
- STD
- FINE
- EX. FINE
- PHOTO
- All LEDs are lit
6. Press
STOP
four times to exit the test.