YES End of procedure.
NO Contact Okidata Technical Support.
YES Replace the MCNT-150 board.
Is the problem resolved?
YES End of procedure.
NO Contact Okidata Technical Support.
POINT - A
YES Does the multi-meter read approximately .27 volts rms?
NO The line may be bad. Call the TELCO for verification.
YES Place the leads of your multimeter across CN7 pins 1 and 2 of the NCU board.
Does the multimeter read approximately .27 volts rms?
YES Replace the MCNT-150 board.
NO Is + 12 vdc present on CN1 pin 14 of the MCNT-150 board and is - 12 vdc present on
CN1 pin 15 of the MCNT-150 board?
NO Replace the PWU-150.
Is the problem resolved?
YES End of procedure.
NO Contact Okidata Technical Support.
YES Replace the NCU-U board.
Is the problem resolved?
YES End of procedure.
NO Replace the LINE-JU board.
Is the problem resolved?
YES End of procedure.
NO Contact Okidata Technical Support.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business